Key specifications at a glance

  • Nominal rating: 51.2 V / 10,240 Wh
  • Cell chemistry: LiFePO4 (LFP)
  • Charge/discharge current: 140 A
  • Scalability: max 18 modules in series per string (921.6 V nominal and approx. 183 kWh with 18 modules; 775–1,040 V DC per the manufacturer's data for the 18-module C183 system), with S920 master module; strings can be paralleled
  • Communication, certification: CAN, RS485; IEC 62619, IEC 63056, UN38.3, CE
  • Operating temperature, protection rating: charge 0–60 °C, discharge −20–60 °C; IP20

Applications

  • Peak shaving at commercial and industrial sites.
  • Self-consumption optimization with solar PV.
  • Energy trading and arbitrage.
  • Emergency and backup power supply.
  • Grid services.
  • Renewable integration in C&I BESS.

e.module H series model and system component

The TAB e.storage C&I catalog lists one module model in the e.module H series. Each series-connected string requires an S920 master module, which is a mandatory system component rather than a separate battery model.

e.module H series model and system component
Model Rating Key feature
TAB e.module H10.2 51.2 V / 10,240 Wh BESS module for high-voltage strings; max 18 in series per string, with S920 master module
TAB e.storage S920 master module max 1,200 V DC / 140 A nominal houses the master BMS and protections; one master module manages up to 18 H10.2 modules, multiple masters can be paralleled

LFP energy storage module technical specifications

LFP energy storage module technical specifications
Parameter Value
Cell chemistry LiFePO4 (LFP)
Nominal voltage 51.2 V
Nominal energy 10,240 Wh
Charge voltage 56.8 V DC
Discharge cut-off voltage 44.8 V DC
Depth of discharge (DoD) 97%
Charge and discharge current 140 A
Scalability max 18 modules in series per string (921.6 V nominal and approx. 183 kWh with 18 modules; 775–1,040 V DC per the manufacturer's data for the 18-module C183 system), with S920 master module; strings can be paralleled
Communication CAN, RS485
Inverter and EMS interfacing according to TAB, voltage and CAN or Modbus communication can be adapted to the inverter and EMS; the precharge circuit is also adaptable
Cooling air-cooled (ventilation)
Operating temperature charge 0–60 °C, discharge −20 to 60 °C
Storage temperature −30 to 45 °C for up to 1 month; −20 to 35 °C for up to 6 months (charge at least every 6 months)
Relative humidity 0–95% (non-condensing)
Altitude max 3,000 m
Protection rating IP20
Dimensions (W × D × H) 391 × 1015 × 165 mm
Weight 110 kg
Certification IEC 62619, IEC 63056, UN38.3, CE
EMC IEC 61000-6-2, IEC 61000-6-3
Manufacturing designed and manufactured in the EU

S920 master module and 18-module string

LFP energy storage module technical specifications
Parameter S920 master module 18-module string (TAB e.storage C183)
Voltage max 1,200 V DC 921.6 V DC nominal; discharge voltage 775 V DC; charge voltage 1,040 V DC (C183 system data)
Current 140 A nominal 140 A
Energy – 183 kWh
Communication CAN, RS485, TCP SunSpec Modbus compatible
Dimensions, weight 442 × 550 × 165 mm; 15 kg –
Environment −20 to 60 °C; 20–95% humidity (non-condensing); max 3,000 m –
Protection rating, compliance IP20; CE, IEC 61000 –

Source: TAB e.storage C&I catalog, V3_05_2026; TAB e.module H10.2 manufacturer product page, November 2026. Specifications are subject to change by the manufacturer.

How to choose

  • String voltage: the string voltage is set by the number of modules in series (51.2 V nominal each). With 18 modules, the string reaches 921.6 V nominal; per the manufacturer's C183 system data, discharge voltage is 775 V DC and charge voltage 1,040 V DC. For the C183 configuration, the inverter's battery-side voltage range must cover the full 775–1,040 V DC range; for other module counts, we check the match against string data agreed with the manufacturer. The 775 V system-level discharge voltage differs from the value derived from the module data (18 × 44.8 V = 806.4 V); we clarify the limit that applies to the configuration with the manufacturer when quoting.
  • Energy and current: an 18-module string provides approx. 183 kWh and 140 A. For more energy or current, connect several strings in parallel, each with its own S920 master module.
  • Inverter and EMS interfacing: according to TAB, voltage, CAN or Modbus communication and the precharge circuit can be adapted to the inverter and EMS. The S920 master module offers CAN, RS485 and TCP, and the C183 string is SunSpec Modbus compatible.
  • Installation environment: the module charges at 0–60 °C and discharges at −20 to 60 °C, with IP20 protection and air cooling. At 110 kg per module, plan the cabinet or rack load rating for the number of strings.

Related services and products

Energom Electronic Kft. is an official distributor of TAB. Services across the Central and Eastern European region; product delivery across Europe. Energom handles sizing of H10.2-based storage systems, allocation of strings and master modules, inverter and EMS interfacing, installation, commissioning and periodic maintenance.

FAQ

How many TAB e.module H10.2 modules can be connected in series?

Up to 18 TAB e.module H10.2 modules can be connected in series per string with an S920 master module, for 921.6 V nominal (775–1,040 V DC per the manufacturer's C183 system data) and approx. 183 kWh. Strings can be paralleled.

What does the S920 master module do?

The S920 master module of a TAB e.module H10.2 string houses the string's master BMS and protection devices, rated for max 1,200 V DC and 140 A nominal. One master module manages up to 18 H10.2 modules, and multiple master modules can be paralleled.

What temperature range does the H10.2 module support?

According to TAB, the module charges at 0–60 °C and discharges at −20 to 60 °C. Storage is permitted at −30 to 45 °C for up to 1 month or at −20 to 35 °C for up to 6 months, with a charge at least every 6 months.

How does the H10.2 connect to an inverter or energy management system?

The module has CAN and RS485 communication; according to TAB, voltage, CAN or Modbus communication and the precharge circuit can be adapted to the inverter or EMS. The S920 master module offers CAN, RS485 and TCP connectivity.

Request a quote

When requesting a quote, include the inverter model and its battery-side (DC) voltage range, the required energy and power, the application (for example peak shaving or backup power) and the environmental conditions at the installation site.

Request a Quote

We respond within 24 hours on business days.

Request a Callback