The portfolio covers Modbus, M-Bus and pulse-output multifunction power analyzers and the matching CT range — for submetering, cost-center billing, peak shaving decision support and energy audits.

Our Products

Eastron SDM120 series (SDM120-M / -MB / -P), single-phase, 45 A

Single-phase, direct-connected, DIN-rail energy meter family up to 45 A for residential and industrial sub-metering and for metering solar PV systems and EV chargers, with bidirectional energy measurement, in Modbus, M-Bus or pulse-output versions, one module wide. Manufactured by Eastron.

Connection
single-phase, direct, 5(45) A; 230 V
Accuracy class
Class B (EN 50470-1/-3); Class 1 (IEC 62053-21)
MID
module B+D; certificate number 0120/SGS0141 according to the datasheet
Communication
RS485 Modbus RTU (SDM120-M), M-Bus (SDM120-MB), pulse only (SDM120-P); 2 pulse outputs
Measured quantities
bidirectional kW and kWh; kvarh, var, VA, V, A, PF, Hz, demand
Width
1 DIN module (18 mm)

Eastron SDM630 series (SDM630-M / -MB / -P and SDM630-Modbus V2), three-phase, 100 A direct

Three-phase, direct-connected, DIN-rail energy meter family up to 100 A for industrial sub-metering, solar inverters and EV chargers, with bidirectional energy measurement and no external auxiliary supply, in Modbus, M-Bus or pulse-output versions, four modules wide. Manufactured by Eastron.

Connection
three-phase (3P4W, 3P3W, 1P2W), direct, 0.3–10(100) A; SDM630-Modbus V2: 0.5–10(100) A; 3 × 230/400 V
Accuracy class
Class B or C (EN 50470-3:2022), Class 1 or 0.5 (IEC 62053-21); SDM630-Modbus V2: Class 1 (IEC 62053-21)
MID
among the direct meters only the SDM630-M is MID-certified (module B+D); the SDM630-Modbus V2 has no MID
Communication
RS485 Modbus RTU (SDM630-M, SDM630-Modbus V2), M-Bus (SDM630-MB), pulse only (SDM630-P); 2 pulse outputs
Measured quantities
bidirectional kW and kWh; kvarh, var, VA, V, A, PF, THD, Hz, max demand
Width
4 DIN modules (72 mm)

Eastron SDM630MCT series, three-phase, CT-connected (1 A / 5 A)

Three-phase, CT-connected, DIN-rail energy meter family for higher-current industrial incomers and feeders and for solar PV zero-export systems, for current transformers with 1 A or 5 A secondary, with bidirectional energy measurement and Modbus or M-Bus communication. Manufactured by Eastron.

Connection
three-phase (3P4W, 3P3W, 1P2W), CT-connected, 1 A or 5 A secondary; 0.05–5(6) A
Accuracy class
Class B or C (EN 50470-3:2022); Class 1 or 0.5S (IEC 62053-22)
MID
module B+D; certificate number 0120/SGS0703; the 333 mV -MV version is not MID
Communication
RS485 Modbus RTU (SDM630MCT), M-Bus (SDM630MCT-MB); 2 pulse outputs
Measured quantities
bidirectional kW and kWh; kvarh, var, VA, V, A, PF, THD, Hz, max demand
Width
4 DIN modules (72 mm)

Eastron SDM630MCT-RC series, three-phase, Rogowski coil, 0.5–10 kA

Three-phase DIN-rail energy meter family for high-current incomers in industrial equipment, PV systems, EV charging stations and data centers, with an integrator-free Rogowski coil input, 0.5–10 kA measuring ranges, bidirectional energy measurement and RS485 Modbus communication, also as a MID-certified version. Manufactured by Eastron.

Connection
three-phase (3P4W, 3P3W, 1P2W), Rogowski coil without integrator; range 0.5 / 1 / 5 / 10 kA; input 85 mV/kA (SDM630MCT-RC) or 100 mV/kA (SDM630MCT-RC MID); separate auxiliary supply
Accuracy class
SDM630MCT-RC: Class 1 (IEC 62053-21), Class B (EN 50470-3:2022); SDM630MCT-RC MID: Class 0.5S (IEC 62053-22), Class C (EN 50470-3:2022)
MID
SDM630MCT-RC MID version only; type examination certificate 0598/MID/B/26/036
Communication
RS485 Modbus RTU; 2 pulse outputs
Measured quantities
bidirectional kWh and kvarh; V, A, kW, var, VA, PF, Hz, max demand
Width
72 mm

Eastron LoRaWAN energy meters (SDM230-Lora / SDM630MCT-Lora)

DIN-rail energy meter family with LoRaWAN communication for sub-metering without communication wiring and for building and site energy management: a single-phase direct-connected version up to 100 A and a three-phase CT-connected version, with bidirectional energy measurement, two pulse outputs and MID certification. Manufactured by Eastron.

Connection
SDM230-Lora: single-phase, direct, 0.15–10(100) A; SDM630MCT-Lora: three-phase, CT-connected, 1 A or 5 A secondary
Accuracy class
SDM230-Lora: Class 0.5 (IEC 62053-21), Class C (EN 50470-3:2022); SDM630MCT-Lora: Class 0.5S (IEC 62053-22), Class C (EN 50470-3:2022)
MID
SDM230-Lora: certificate T12800; SDM630MCT-Lora: 0598/MID/B/24/036 (0120/SGS0703)
Communication
LoRaWAN 1.0.2, Class C, OTAA or ABP, EU868; 2 pulse outputs; no RS485
Measured quantities
bidirectional kWh and kvarh; V, A, kW, var, VA, PF, Hz, max demand
Width
2 DIN modules (36 mm, SDM230-Lora); 4 DIN modules (72 mm, SDM630MCT-Lora)

Eastron ESCT-RC Rogowski coils, 16–240 mm window size

Flexible, openable Rogowski coil family for current measurement on large or hard-to-reach conductors, with 16–240 mm window sizes and a 2 m lead, connecting to Eastron Rogowski-input energy meters without an external integrator and with no danger from an open-circuited secondary. Manufactured by Eastron.

Output signal
85 mV/kA at 50 Hz (Ø8 mm types: ESCT-RC60 … RC240); 50 mV/kA (Ø6 mm types: ESCT-RC16, RC24, RC36)
Accuracy
calibrated <0.5% (central position, 25 °C); linearity ±0.2% of reading; position error max ±1%; phase error ≤0.5°
Window size
16 / 24 / 37 mm (Ø6 mm coil); 50–240 mm (Ø8 mm coil)
Lead
2 m, blue (+) and black (−) wire; length customizable
Operating temperature
−30 to +80 °C
Compatible meters
Eastron SDM630MCT-RC (ESCT-RC60 / RC100 / RC150)

Eastron DCM230 series (DCM230-1 / DCM230-2), DC

DIN-rail DC energy meter family for DC-side metering in solar PV, battery and industrial DC systems and in EV charging stations, with an external shunt current input, bidirectional energy measurement and RS485 Modbus RTU communication, two modules wide. Manufactured by Eastron.

Measurement voltage
5–300, 5–600 or 5–1,000 V DC (version dependent); DCM230-2-150 … -800: 100–1,000 V DC
Current input
external shunt, 75 mV (60 or 45 mV optional); DCM230-2-150 … -800: 150–800 A rated
Accuracy class
Class 1 (IEC 62053-41 / GB/T 33708-2017)
Communication
RS485 Modbus RTU + 1 pulse output
Measured quantities
bidirectional (import and export kWh); W, V, A
Width
2 DIN modules (36 mm)

Eastron DCM6 series (DCM6-650 / DCM6-200), DC, 150–1,000 V

DIN-rail DC energy meter family for direct installation in DC fast charging stations, for legally compliant billing of charging processes, with a 150–1,000 V measurement range, 200 or 650 A maximum current, an integrated shunt, signed measurement data and line loss calculation. Manufactured by Eastron.

Measurement voltage
150–1,000 V DC
Current input
integrated shunt, direct connection; max 650 A (DCM6-650), max 200 A (DCM6-200); line loss calculation in 2-wire or 4-wire mode
Accuracy class
Class B (EN 50470-4:2023)
MID, Eichrecht
MID: type examination certificate T12796 (module B, NMi Certin); Eichrecht: T12796-DE
Communication
2 × RS485 Modbus RTU; signed OCMF 1.2.0 datasets (ECDSA secp256r1); LCD display
Measured quantities
bidirectional active energy; V, A, kW, line loss; storage of more than 225,000 charging records

How to Choose an Energy Meter or Current Transformer?

Selecting the right metering device depends on application objective and the current range to be measured. The criteria below help frame the procurement.

Meter or current transformer?

An energy meter directly measures voltage, current, power and energy. A current transformer (CT) steps currents above the direct-measurement limit (in our range, depending on the model: the single-phase SDM120 measures directly up to 45 A, the single-phase SDM230-Lora and the three-phase SDM630 up to 100 A) down to a safe measuring range for the meter — the two together form the complete measurement chain.

Submetering vs. billing-grade accuracy

A certified (MID) meter is required where the measurement is used as a legal billing basis (e.g. tenant invoicing). Submetering and internal cost-center billing typically do not require MID certification — here the accuracy class (Class 0.5 or 1) is the right reference.

Communication

Modbus RTU/TCP is the most common industrial protocol, M-Bus is widespread in building services, pulse output (S0) is the simplest integration. The existing SCADA / EMS / BMS protocol drives the choice.

CT ratio and accuracy class

The primary side of the ratio (primary/secondary current, e.g. 100/5 A, 600/5 A) should be sized to the maximum expected current — an oversized CT is inaccurate at low loads. Class 0.2 / 0.5 / 1 should match the requirement.

Installation form factor

DIN-rail or panel-mount meter; solid-core or split-core (clamp-on) current transformer, or flexible Rogowski coil. Available cabinet space and access requirements (split-core CTs or Rogowski coils are preferable for retrofit) drive the choice.

Functionality

Simple kWh meter, multifunction network analyzer (THD, harmonics, phase imbalance, peak demand logging), or power quality (PQ) analyzer — depending on the application complexity.

Decision guide

SituationRecommended solutionWhyNext step
Internal cost-center billing, submetering Meter selected by accuracy class (Class 0.5 or 1) MID certification is typically not required Industrial energy management
Re-billing (e.g. to tenants) MID-certified meter Legal billing basis Request a quote
High current, existing cabinet CT-connected meter with split-core CT or Rogowski coil Retrofit without disconnecting conductors Monitoring and optimization
Solar or battery DC circuit DC energy meter Measures DC energy C&I energy storage
Data needed in the EMS Meter with Modbus RTU/TCP or M-Bus output Direct integration Energy management systems

The Energom advantage

  • Measurement chain designed from CT to EMS by a single partner.
  • Energy audit and submetering project experience.
  • Modbus / M-Bus integration into energy management systems.

Request a Custom Quote

We recommend a configuration based on the target application (submetering, energy audit, EMS input) and the existing infrastructure.

Request a Quote Request a Callback

We respond to quote requests within 24 hours on business days and return callback requests within 4 business hours.