Design and Installation — UPS, DC and EV Charging Systems From a Single Accountable Partner

A wrongly sized UPS, an undersized battery bank or a poorly integrated EV charging infrastructure can generate failures on commissioning day — or worse, only months later, during the first real outage. Energom Electronic Kft. designs from the task, not the brand: we choose from the 13 manufacturers we distribute and integrate other manufacturers' equipment where needed. 25+ years of experience in power plant, railway, data center and hospital environments — one accountable partner from consultation to handover. We provide our services across the Central and Eastern European region and deliver products across Europe.

Consulting

Needs analysis starts where you are. New facility, expansion of an existing system, technology change or relocation — each calls for a different question set. During consultation our engineer maps the critical loads, the redundancy requirement (N+1, 2N), the backup time target, the constraints of the existing infrastructure and future scalability. The first consultation is free of charge, with no obligation — it ends with a written proposal outline you can use to move forward in your own decision process.

When you need it:

  • preparing a new investment
  • taking over operation of an existing system
  • technology change decisions (e.g. monoblock → modular UPS)
  • relocation
  • pre-SLA mapping.

Site Survey

You can't design a complex power system from a catalog. During the site survey we record the physical conditions (space constraints, cable routes, cooling, floor load), the existing infrastructure (grid connection, existing UPS/battery/generator, BMS), environmental factors (temperature, humidity, fire protection) and operational constraints (downtime window, accessibility). The survey concludes with a written report — the basis of every subsequent design and quotation step.

When you need it:

  • before designing a new system
  • before taking over an existing system (new owner, new operator)
  • before significant expansion or retrofit
  • for root-cause analysis of recurring outages.

Instrumented Measurement

Where survey relies on inspection, instrumented measurement relies on hard data. Power quality audit (total harmonic distortion – THD, power factor – PF, line disturbances), actual load profile via 7-14 day data-logger measurement, battery capacity test by load-bank discharge (Cn, 10/20/100-hour rate), thermal imaging, current transformer (CT) measurements. The report is quantitative — sizing decisions are based on measured data, not assumptions.

When you need it:

  • sizing a new UPS for actual (not nominal) load
  • suspecting power quality issues (errors, equipment failures)
  • determining true remaining capacity of an existing battery bank before replacement
  • audit / due diligence.

System Design

Design is manufacturer-independent and tuned to the actual technical and business constraints: redundancy level (N, N+1, 2N, 2N+1), topology (centralized vs. modular vs. distributed), backup time (5/10/15 minutes or hours of autonomy), communication interfaces (SNMP, Modbus, BACnet) and connection to data center infrastructure management (DCIM). Documentation includes single-line diagrams, schematic drawings, sizing calculations, environmental and fire protection data — and a concurrently maintainable topology (e.g. per Tier III) where required.

When you need it:

  • new investment
  • significant capacity expansion
  • technology modernization of an existing system
  • design documentation for audit or regulatory approval.

Full Installation

One accountable partner — from delivery to the last point of the connection test. Procurement of equipment from the designed manufacturers, on-site delivery, mechanical assembly, cabling (power and low-voltage), conduit, battery bank assembly and connection, communication network installation. Work scheduled to the planned downtime window, with documented HSE and quality assurance — 25+ years of railway, hospital and data center work brings this discipline.

When you need it:

  • new power system installation
  • complex expansion in an existing facility
  • relocation with reinstallation.

Commissioning

Installation is not commissioning. During commissioning we configure parameters, calibrate protection, test the bypass switch, perform the initial battery bank capacity test, configure communication interfaces (SNMP/Modbus/BACnet) and run a full system load test (load bank where required). The client receives a written handover report with initial settings — the reference point for all future maintenance.

When you need it:

  • new system start-up
  • after major retrofit or modular UPS expansion
  • to fulfill manufacturer commissioning requirements (warranty condition).

Integration With Other Systems

Power supply does not live on an island. In a modern facility UPS, battery bank, generator and EV charging infrastructure integrate with building management (BMS), energy management (EMS), fleet management software or industrial SCADA. SNMP, Modbus TCP, BACnet IP, OCPP 1.6J / 2.0.1, REST API — we build the communication layer so alarms reach the right place and operational data drives measurable decisions.

When you need it:

  • new system start-up with EMS/BMS integration
  • connecting an existing system to monitoring software
  • placing EV charging infrastructure behind an OCPP-compatible charge point management system (CPMS)
  • consolidated supervision of multi-site systems.

Training

Handover day is not the last day operators or maintenance engineers should learn something about the system. At commissioning we deliver operator training (daily operations, alarm handling, emergency procedure), and on request advanced engineering training (parameter configuration, fault diagnosis, battery maintenance workshop). Materials are tailored to the specific installed system — not a generic manufacturer brochure.

When you need it:

  • as part of commissioning
  • upon takeover by a new operator team
  • after expansion / technology change
  • for in-house engineer competence development.

Not Sure Which Service You Need?

Let's Talk About Your Project

Tell us where you are and your timeline — the first consultation is free of charge. We respond within 24 hours on business days; if the exact quote needs technical data, we will follow up with you.

Request a Technical Quote Request a Callback

25+ years of service and installation experience · manufacturer-independent design · in-house engineering team, in-house tools and instruments · 1,000+ installed systems.