Monitoring and Optimization — Proactive Supervision and Energy Efficiency
The system is running — but how much is it telling you about itself? A production line outage rarely arrives without warning: capacitor degradation, battery internal resistance drift, growing line distortion are measurable weeks or months before the failure event. The only difference is whether someone is watching. Energom Electronic Kft.'s monitoring and optimization services are proactive and preventive, and manufacturer-independent: alongside the Riello UPS, Delta Electronics, Eltek, Eastron and Hoymiles equipment we distribute, we monitor and optimize other manufacturers' equipment as well. 25+ years of operational experience — including continuously operating critical systems in data centers, hospitals and manufacturing plants. We provide this service across the Central and Eastern European region.
Power Quality Audit + Predictive Maintenance Advisory
Measurement-based condition assessment and forecasting. 7-14 day power quality data-logger measurement (total harmonic distortion – THD, power factor – PF, line disturbances, phase asymmetry, load profile), battery bank trend analysis (Ri drift, capacity decay curve), thermal imaging hot-spot inspection, control board and capacitor ESR analysis. The audit deliverable is not a fault list but a predictive maintenance roadmap: which component is expected to need replacement in 6 / 12 / 24 months, with what priority, at what estimated cost. The written report supports CAPEX planning — instead of reactive firefighting.
When you need it:
- preparing annual CAPEX/OPEX planning
- taking over an unfamiliar system as a new operator
- introducing ISO 50001 or similar energy standard
- recurring faults of unclear origin
- 5+ year old system where lifetime risk grows.
Remote Monitoring
Continuous (24/7) data recording and alarming, proactive intervention. We continuously record parameters via the communication interfaces of UPS, battery banks, generators and energy storage systems (SNMP v3, Modbus TCP, BACnet IP, manufacturer cloud protocols): load, battery voltage, temperature, alarms, error codes. Critical events are assigned to an Energom engineer — human assessment, not just automatic email forwarding; alarm evaluation and intervention times are set in the individual contract. The infrastructure can be integrated into existing DCIM, BMS or SCADA — or used as a standalone monitoring interface.
When you need it:
- critical operation where every alarm must arrive within hours
- multi-site system requiring consolidated supervision
- supplementing in-house operator night/weekend coverage
- new facility start-up where initial stabilization is safer with an external eye
- audit requirement (auditable service history).
AI-Based Services
Predictive analysis and anomaly detection on accumulated operational data. Telemetry from remote monitoring and periodic inspection runs through machine learning models that highlight behavioral patterns hard to see by eye: slow battery capacity drift, load pattern changes, cooling efficiency degradation, communication latency patterns. Anomaly-based alerting aims to produce fewer false alarms and earlier warnings than threshold-based alarms.
When you need it:
- large telemetry datasets accumulating without evaluation
- multi-site system where comprehensive manual evaluation is not feasible
- introducing a predictive maintenance strategy
- industrial client where human monitoring capacity is constrained.
Note: AI services build on existing monitoring infrastructure — the first step is always remote monitoring configuration.
Energy Management Optimization
The power supply system is not only a reliability concern — it is also an energy cost factor. EMS (energy management system) introduction and optimization: metering (submeters, current transformers), load profile analysis, peak shaving with energy storage, self-consumption optimization with solar inverter, dynamic tariff utilization. We track the result with measured data. Savings and payback period are project-specific; we calculate them from 15-minute metering data, the tariff and the contracted capacity.
When you need it:
- high and rising energy cost
- new industrial capacity expansion (peak load growth expected)
- solar or energy storage system installed without optimization strategy
- introducing an ISO 50001 energy management system
- auditable energy result requirement.
Not Sure Which Service You Need?
- No remote monitoring, system runs without meaningful data → Remote Monitoring
- High and growing energy cost → Energy Management Optimization
- Recurring faults of unclear origin → Power Quality Audit and Predictive Maintenance Advisory
- Multi-site system, plenty of telemetry, little evaluation → AI-based anomaly detection
- CAPEX plan being prepared with 1-2 year horizon → Power Quality Audit and predictive maintenance roadmap