The chosen topology depends on objective: grid feed-in (with self-consumption optimization), hybrid storage with self-consumption priority, or off-grid-capable. Inverter sizing, MPPT channel count and grid connection requirements are driven by roof structure and consumption profile.

Our Products

Hoymiles HMT-1600 / 1800 / 2000-4T, 1,600–2,000 VA

Three-phase microinverter family for commercial and industrial rooftops, with 1,600–2,000 VA rated output power, for connecting four PV modules, with two MPPTs, a low-voltage DC side, galvanic isolation, an integrated grid protection relay and Sub-1G wireless communication. Manufactured by Hoymiles.

Rated AC power
1600 / 1800 / 2,000 VA; 230/400 V, three-phase
DC input
max 65 V; 2 MPPTs, 2 inputs per MPPT (4 modules); MPPT range 16–60 V; 4 × 14–16 A
Efficiency
peak efficiency 96.5% (stated as CEC peak efficiency on the datasheet)
Grid compliance
VDE-AR-N 4105:2018, EN 50549-1:2019
Protection rating
IP67
Models
HMT-1600-4T, HMT-1800-4T, HMT-2000-4T

Hoymiles HYT-(5-12)HV-EUG1, 5–12 kW

Three-phase hybrid inverter family for residential and small commercial solar-plus-storage systems, for high-voltage batteries, rated 5–12 kW, with two MPPT inputs, backup operation with switchover under 10 ms and 100% three-phase unbalanced output. Manufactured by Hoymiles.

Rated AC power
5–12 kW; max 5.5–12 kVA; 380/400 V, 3L/N/PE
DC input
max 1,000 V; 2 MPPTs, 200–950 V; 14/14 A (5–8 kW), 14/28 A (10–12 kW)
Efficiency
max 98.0%; European 97.0–97.5% (97.5% applies to the 12 kW model only)
Battery
170–600 V; max 20 A (5–6 kW), 30 A (8–12 kW); max 5–10 kW charge/discharge
Backup operation
peak 10–16 kVA for 10 s; switchover <10 ms
Compliance, protection rating
EN 50549, VDE-AR-N 4105; IP65

Hoymiles HIT-(5-20)L-G3 / G3S, 5–20 kW

Three-phase hybrid inverter family for residential and small commercial solar-plus-storage systems, for low-voltage (40–60 V) batteries, rated 5–20 kW, with two to four MPPT inputs, backup operation with switchover under 10 ms, 100% unbalanced output and an integrated 50 A bypass. Manufactured by Hoymiles.

Rated AC power
5–20 kW; max 5.5–22 kVA; 380/400 V, 3L/N/PE
DC input
max 1,000 V; MPPT 150–900 V; 2 MPPTs (5–6 kW), 3 MPPTs (8–10 kW), 4 MPPTs (12–20 kW); 20 A per MPPT
Efficiency
max 98.2%, European 97.6% (5–10 kW); max 98.5%, European 98.0% (12–20 kW)
Battery
40–60 V; Li-ion or lead-acid; max charge/discharge current 120–350 A
Backup operation
rated 5–20 kW; peak 10–40 kVA for 10 s if PV and battery power are sufficient; switchover <10 ms
Compliance, protection rating
EN 50549, VDE 4105, TOR Erzeuger Type A; IEC 62109-1/-2; IP66

Solis S6-GC 25–150 kW

Three-phase grid-tied string inverter family for commercial and industrial rooftops and ground-mounted solar PV systems, rated 25–150 kW, with 1,100 V maximum DC voltage, 3–10 MPPT inputs depending on the model, IP66 protection and a night-time reactive power (SVG) function. Manufactured by Solis.

Rated AC power
25–150 kW; 3/N/PE, 230/400 V; 110% apparent power only for the 80, 100, 110 and 150 kW models
DC input
max 1,100 V; 3–10 MPPTs / 6–21 strings; MPPT range 180–1,000 V (25–60 kW), 160–1,000 V (80–150 kW)
Input current per MPPT
42 A (25–60 kW); 42 A / 36 A (80–125 kW); 54 A (150 kW)
Efficiency
max 98.5–98.8%; European 98.0–98.3% (model dependent)
Grid compliance
EN 50549-1, VDE-AR-N 4105 (25–60 kW); EN 50549-1/-2, VDE 4110 (80–150 kW)
Protection rating, protections
IP66; AFCI 2.0 optional; Type II DC / Type II AC surge protection (40–150 kW)

Solis S6-EH3P(30-60)K-H(21A) 30–60 kW

Three-phase hybrid inverter family for commercial solar-plus-storage systems, for high-voltage batteries, rated 30–60 kW, with three or four MPPT inputs, two independent battery ports, a generator input, backup operation with switchover under 10 ms and parallel operation of up to six units. Manufactured by Solis.

Rated AC power
30 / 40 / 50 / 60 kW; max 30–60 kVA; 3/N/PE, 230/400 V
DC input
max 1,000 V; MPPT 150–850 V; 3 MPPTs / 6 strings (30 kW), 4 MPPTs / 8 strings (40–60 kW); 42 A per MPPT, 21 A per string
Efficiency
max 97.7%; European 97.3%
Battery
Li-ion, 150–800 V; 2 battery ports; max 80 A per port (30–50 kW), 84 A (60 kW)
Backup operation
rated 30–60 kW; 1.6 × rated power for 2 s, 1.5 × for 10 s; switchover <10 ms (<20 ms in parallel systems)
Compliance, protection rating
EN 50549-1 / EN 50549-10 (TÜV Rheinland certificate); EN 62109-1/-2; IP66

How to Choose a C&I Solar Inverter?

For commercial and industrial PV installations, inverter selection is not a stand-alone decision — array layout, grid connection and optional storage together drive the architecture.

Hybrid or non-hybrid

A hybrid inverter is the right choice where battery storage (self-consumption optimization or backup) is part of the system. Non-hybrid is preferable where the system only feeds the grid and storage is handled as a separate system — or planned for later expansion.

String inverter or microinverter

String inverters (25–150 kW in our range) for rooftop and ground-mounted systems; with multiple MPPTs they also suit mixed-orientation roofs. Microinverters are preferable where MPPT per small module group is needed — on fragmented or partly shaded roofs — and a low-voltage DC side is required. Central inverters are not part of our range; larger installations typically use several string inverters in parallel.

MPPT channel count and orientation

Mixed-orientation roofs or shaded sections require multiple MPPT channels — driven by an orientation and shading analysis at design stage.

Grid connection and power control

The grid connection agreement (active power curtailment, dynamic feed-in control) and operator requirements (VDE-AR-N 4105, MSZ EN 50549) are part of inverter selection. Reactive power control and frequency-dependent active power control can be mandatory.

Monitoring and yield measurement

Inverter portal or third-party monitoring — Modbus TCP, SunSpec, REST API. Accurate yield measurement and fault reporting are the basis of operation.

Service life and spare-parts availability

A C&I PV installation runs in a 20-25 year lifecycle. The inverter is typically replaced after 10-15 years — long-term manufacturer support and spare-parts policy are part of TCO.

Decision guide

SituationRecommended solutionWhyNext step
Storage now or later Hybrid inverter (5–60 kW) Handles PV, battery and grid in one unit Industrial batteries
Grid feed-in only, larger roof or ground mount String inverter (25–150 kW) Multiple MPPTs, higher unit power Industrial energy management
Fragmented or partly shaded roof Three-phase microinverter (1,600–2,000 VA) MPPT per small module group, low-voltage DC side Request a quote
Complete system with storage Joint sizing of inverter and energy storage Self-consumption optimization and backup C&I energy storage

The Energom advantage

  • Integrated design of hybrid PV + storage configurations.
  • Official Hoymiles and Solis distribution, with sizing and installation.
  • Familiarity with grid connection documentation and authority processes.