Hoymiles HMT-1600/1800/2000-4T 1600–2000 VA Three-Phase Microinverter
The Hoymiles HMT-1600/1800/2000-4T is a 1600–2000 VA three-phase 4-in-1 microinverter range that connects four PV modules per unit. Built with two MPPTs, a low-voltage DC side rated up to 65 V, galvanic isolation and IP67 protection, the range targets commercial and industrial rooftop solar PV systems, with module-level monitoring via Sub-1G wireless communication and S-Miles Cloud.
Key specifications at a glance
- Rated AC power: 1600 / 1800 / 2000 VA; 230/400 V, three-phase
- DC input: max 65 V; 2 MPPTs, 2 inputs per MPPT (4 modules); MPPT range 16–60 V; 4 × 14–16 A
- Efficiency: peak efficiency 96.5% (stated as CEC peak efficiency on the datasheet)
- Grid compliance: VDE-AR-N 4105:2018, EN 50549-1:2019
- Protection rating: IP67
- Models: HMT-1600-4T, HMT-1800-4T, HMT-2000-4T
Applications
- Commercial and industrial rooftop solar PV systems with a three-phase (230/400 V) grid connection.
- Installations that require module-level monitoring and remote O&M through S-Miles Cloud.
- Rooftop arrays built with 182 mm and 210 mm cell PV modules, with one 4-in-1 microinverter serving four modules.
HMT-4T microinverter models
| Model | Rated output power | Key differentiator |
|---|---|---|
| HMT-1600-4T | 1600 VA | max 14 A per input; commonly used module power 320–540+ W |
| HMT-1800-4T | 1800 VA | max 15 A per input; commonly used module power 360–600+ W |
| HMT-2000-4T | 2000 VA | max 16 A per input; commonly used module power 400–670+ W |
Hoymiles HMT-4T microinverter specifications
| Parameter | Value |
|---|---|
| Rated output power | 1600 / 1800 / 2000 VA (HMT-1600-4T / HMT-1800-4T / HMT-2000-4T) |
| Rated output current | 3 × 2.32 A (HMT-1600-4T); 3 × 2.61 A (HMT-1800-4T); 3 × 2.9 A (HMT-2000-4T) |
| Grid connection | 230/400 V, 3W+N+PE; 50 Hz |
| Power factor | > 0.99 (default; adjustable) |
| Total harmonic distortion | < 3% |
| Max DC input voltage | 65 V |
| MPPT voltage range | 16–60 V |
| Start-up voltage (min / max) | 22 V / 60 V |
| MPPTs and inputs | 2 MPPTs, 2 inputs per MPPT (4 PV modules) |
| Max input current | 4 × 14 A (HMT-1600-4T); 4 × 15 A (HMT-1800-4T); 4 × 16 A (HMT-2000-4T) |
| Max input short-circuit current | 4 × 25 A |
| Commonly used module power | 320–540+ W (HMT-1600-4T); 360–600+ W (HMT-1800-4T); 400–670+ W (HMT-2000-4T) |
| Compatible modules | PV modules with 182 mm and 210 mm cells |
| Peak efficiency | 96.5% (stated as CEC peak efficiency); the datasheet does not state a European weighted efficiency |
| Nominal MPPT efficiency | 99.8% |
| Night-time power consumption | < 50 mW |
| Isolation | galvanically isolated HF transformer |
| Grid protection | integrated grid protection relay |
| Cooling | natural convection, no fans |
| Protection rating | IP67 |
| Ambient temperature range | −40 to +65 °C |
| Storage temperature range | −40 to +85 °C |
| Dimensions (W × H × D) | 326 × 222 × 40.6 mm |
| Weight | 5.9 kg |
| Communication, monitoring | Sub-1G wireless link to the Hoymiles DTU gateway; module-level monitoring in S-Miles Cloud |
| Grid compliance | VDE-AR-N 4105:2018; EN 50549-1:2019; VFR 2019 |
| Safety, EMC | IEC/EN 62109-1/-2; IEC/EN 61000-6-1/-2/-3/-4; IEC/EN 61000-3-2/-3 |
Source: Hoymiles microinverter datasheet (EMEA & APAC region), V202302; Hoymiles EU product page, November 2026. Specifications are subject to change by the manufacturer.
How to choose
Module power and model
Start from the power and current of the PV modules you plan to connect. The datasheet lists these commonly used module power ranges:
| PV module | Suggested model | Why |
|---|---|---|
| 320–540+ W | HMT-1600-4T | max 14 A per input, 1600 VA output |
| 360–600+ W | HMT-1800-4T | max 15 A per input, 1800 VA output |
| 400–670+ W | HMT-2000-4T | max 16 A per input, 2000 VA output |
DC-side matching
- The module operating current should fit the max input current of 14, 15 or 16 A per input; max input short-circuit current is 4 × 25 A.
- The module MPP voltage should sit within the 16–60 V MPPT range, and its open-circuit voltage at the lowest expected temperature must not exceed the 65 V max DC input voltage; start-up voltage is 22 V.
Grid connection and monitoring
- The microinverter output is three-phase (230/400 V, 3W+N+PE, 50 Hz), with grid compliance to VDE-AR-N 4105:2018 and EN 50549-1:2019.
- Sub-1G communication runs through the Hoymiles DTU gateway, so the DTU needs a place in the system design for module-level monitoring.
- For outdoor rooftop locations, the relevant data points are IP67 protection, the −40 to +65 °C ambient range and fanless cooling.
Related services and products
- C&I solar inverters – the full category
- Design and installation – PV system sizing, installation and commissioning
- Monitoring and optimization – monitoring setup and operational support
- Industrial energy management – coordinating generation, storage and consumption
- Hoymiles HYT-(5-12)HV-EUG1 hybrid inverter
- Hoymiles HIT-(5-20)L-G3 / G3S hybrid inverter
Energom Electronic Kft. is an official distributor of Hoymiles. Services across the Central and Eastern European region; product delivery across Europe. Energom handles microinverter PV system sizing, module-to-inverter matching checks, installation, commissioning and monitoring setup.
FAQ
How many PV modules can one Hoymiles HMT-4T microinverter handle?
The HMT-1600-4T, HMT-1800-4T and HMT-2000-4T each have two MPPTs with two inputs per MPPT; max input current is 14, 15 or 16 A per input depending on the model.
Which grid standards does the Hoymiles HMT-4T meet?
According to the datasheet, the Hoymiles HMT-4T complies with VDE-AR-N 4105:2018, EN 50549-1:2019 and VFR 2019; the listed safety standard is IEC/EN 62109-1/-2.
Does the Hoymiles HMT-4T require a DTU gateway?
The DTU is needed for module-level monitoring: HMT-4T microinverters communicate with the Hoymiles DTU gateway over a Sub-1G wireless link, and module-level data is available in S-Miles Cloud, so the DTU needs a place in the system design.
Request a quote
When requesting a quote, include the PV module type, power and quantity, the roof layout, grid connection details and your monitoring requirements.
We respond within 24 hours on business days.