Key specifications at a glance

  • Rated AC power: 5–12 kW; max 5.5–12 kVA; 380/400 V, 3L/N/PE
  • DC input: max 1000 V; 2 MPPTs, 200–950 V; 14/14 A (5–8 kW), 14/28 A (10–12 kW)
  • Efficiency: max 98.0%; European 97.0–97.5% (97.5% applies to the 12 kW model only)
  • Battery: 170–600 V; max 20 A (5–6 kW), 30 A (8–12 kW); max 5–10 kW charge/discharge
  • Backup operation: peak 10–16 kVA for 10 s; switchover <10 ms
  • Compliance, protection rating: EN 50549, VDE-AR-N 4105; IP65

Applications

  • Solar-plus-storage systems with self-consumption optimization (self-consumption mode).
  • Economy mode (tariff-based) for scheduling battery charging and discharging.
  • Peak shaving by capping the power drawn from the grid, and time-of-use (TOU) charge and discharge scheduling with up to eight periods.
  • Backup power with switchover under 10 ms during grid outages.
  • Export limitation at sites with a restricted grid connection.
  • Generator and load control via dry contact.

HYT-HV hybrid inverter models

HYT-HV hybrid inverter models
Model Rated power Key differentiator
HYT-5.0HV-EUG1 5 kW battery max 20 A / 5 kW; European efficiency 97.0%
HYT-6.0HV-EUG1 6 kW battery max 20 A / 6 kW; European efficiency 97.1%
HYT-8.0HV-EUG1 8 kW battery max 30 A / 8 kW; European efficiency 97.2%
HYT-10.0HV-EUG1 10 kW MPPT 2 rated 28 A (2 strings); European efficiency 97.4%
HYT-12.0HV-EUG1 12 kW MPPT 2 rated 28 A (2 strings); European efficiency 97.5%

Hoymiles HYT-HV hybrid inverter specifications

Hoymiles HYT-HV hybrid inverter specifications
Parameter Value
Rated AC power 5 / 6 / 8 / 10 / 12 kW; max 5.5–12 kVA
Grid voltage, frequency 380/400 V, 3L/N/PE; range 266–480 V; 50/60 Hz
Max output current (on-grid and backup) 8.3 / 10.0 / 13.3 / 16.7 / 17.4 A (5 / 6 / 8 / 10 / 12 kW model)
Max AC input power from grid 10 / 12 / 16 / 16 / 16 kW (5 / 6 / 8 / 10 / 12 kW model)
Power factor, current distortion > 0.99 (0.8 leading … 0.8 lagging); THDi < 3% at rated output
Max DC input voltage 1000 V
Rated and start-up DC voltage rated 720 V; start-up 250 V
MPPT voltage range 200–950 V
MPPTs / max input strings 2 / 2 (5–8 kW); 2 / 3 (10–12 kW)
Max input current per MPPT 14/14 A (5–8 kW); 14/28 A (10–12 kW)
Max short-circuit current per MPPT 17/17 A (5–8 kW); 17/34 A (10–12 kW)
Recommended max PV power 7.5 / 9 / 12 / 15 / 15 kW (5 / 6 / 8 / 10 / 12 kW model); DC/AC ratio up to 150% (125% for the 12 kW model)
Battery Li-ion, 170–600 V; max 20 A (5–6 kW), 30 A (8–12 kW); max 5–10 kW charge/discharge; charging self-adapting to BMS; CAN
Backup operation peak 10–16 kVA for 10 s; switchover < 10 ms; THDv < 3% at linear load
Max efficiency 98.0% (all models)
European efficiency 97.0 / 97.1 / 97.2 / 97.4 / 97.5% (5 / 6 / 8 / 10 / 12 kW model)
MPPT efficiency 99.9%
Max battery discharge to AC efficiency 97.5%
Integrated protections anti-islanding; PV reverse polarity protection; insulation resistance detection; residual current monitoring unit (RCMU); AC overcurrent, short-circuit, over- and undervoltage protection
Surge protection Type II DC / Type III AC
Protection rating IP65
Dimensions (W × H × D), weight 502 × 486 × 202 mm; 26.5 kg
Operating temperature −25 to +65 °C (derating above 45 °C)
Relative humidity, altitude 0–95%, non-condensing; ≤ 2000 m
Cooling, topology natural convection; transformerless (solar and battery side)
Noise < 40 dB
User interface, digital I/O LED, app; DRM, 1 × DI, 2 × DO (DO1 dry contact configurable for earth-fault alarm, load or generator control; DO2 controls the bypass contactor)
Communication RS485; optional Wi-Fi
Parallel operation max 10 inverters, including models of different power ratings; one battery cannot be shared between inverters
Grid compliance EN 50549; VDE-AR-N 4105; VFR 2019; TOR Erzeuger Type A; RD 647; NTS (SENP); CEI 0-21 2019:04
Safety, EMC IEC 62109-1/-2; EN 61000-6-1/-3

Source: Hoymiles HYT-HV Series datasheet (Global), REV1.7 (2025); Hoymiles HYT-HV-EUG1 user manual (Global), REV2.6 (2025-11); Hoymiles EU product page, November 2026. Specifications are subject to change by the manufacturer.

How to choose

Power rating and PV array

How to choose
Situation Suggested model Why
7.5–12 kW PV array depending on the model, two strings HYT-5.0HV-EUG1, HYT-6.0HV-EUG1 or HYT-8.0HV-EUG1 2 MPPTs / 2 strings, 14 A per MPPT
PV array up to 15 kW, three strings HYT-10.0HV-EUG1 or HYT-12.0HV-EUG1 MPPT 2 rated 28 A with 2 strings; 3 strings in total
System power above 12 kW several HYT-HV inverters in parallel per the user manual up to 10 inverters, including different power ratings; one battery cannot be shared between inverters

Recommended max PV power ranges from 7.5 to 15 kW depending on the model, with a DC/AC ratio of up to 150% (125% for the 12 kW model).

Battery

  • The HYT-HV works with high-voltage Li-ion batteries in the 170–600 V range over CAN; charging self-adapts to the BMS.
  • Max charge and discharge current is 20 A on the 5–6 kW models and 30 A on the 8–12 kW models; charge and discharge power is up to 5–10 kW.

Backup operation and grid connection

  • In backup operation, peak power is 10–16 kVA for 10 s depending on the model, with switchover under 10 ms.
  • Grid compliance covers EN 50549 and VDE-AR-N 4105; the protection rating is IP65, and derating applies above 45 °C.

Related services and products

Energom Electronic Kft. is an official distributor of Hoymiles. Services across the Central and Eastern European region; product delivery across Europe. Energom handles hybrid inverter system sizing, battery compatibility checks, installation, commissioning and energy management mode configuration.

FAQ

Which batteries work with the Hoymiles HYT-HV hybrid inverter?

The Hoymiles HYT-(5-12)HV-EUG1 works with high-voltage Li-ion batteries in the 170–600 V range with CAN communication. Max charge and discharge current is 20 A (5–6 kW) or 30 A (8–12 kW), and charging self-adapts to the BMS.

Can the Hoymiles HYT-HV be paralleled?

According to the datasheet and the user manual, up to 10 Hoymiles HYT-(5-12)HV-EUG1 inverters can be connected in parallel. The user manual allows models of different power ratings in one parallel system, but one battery cannot be connected to more than one inverter at a time.

How fast does the HYT-HV switch to backup operation?

Hoymiles HYT-(5-12)HV-EUG1 switchover takes less than 10 ms. In backup operation, peak power is 10–16 kVA for 10 s depending on the model, and output voltage distortion is THDv < 3% at linear load.

How much PV capacity can be connected to the HYT-HV?

Hoymiles HYT-(5-12)HV-EUG1 recommended max PV power is 7.5 kW (5 kW model), 9 kW (6 kW), 12 kW (8 kW) and 15 kW (10 and 12 kW), so the DC/AC ratio is up to 150%, or 125% for the 12 kW model.

Request a quote

When requesting a quote, include the PV array power (and the string layout, if already available), the planned battery type and capacity, the loads to be supplied in backup operation and your grid connection details.