From data centers to railways, from hospitals to manufacturing — wherever power supply is a matter of business continuity. Since 1998, Energom Electronic Kft. has been designing, installing and maintaining power systems in critical industrial environments. Our solutions are tailored to the specific requirements of eight industries — by standards profile, redundancy level, autonomy demand and typical site context.
Data centers
Typical problem: Even a short power loss carries the risk of service disruption, data loss and — depending on the contract — an SLA breach. Tier III/IV-style requirements may demand concurrent maintainability or fault tolerance — maintainability and redundancy must be proven at full system-architecture level. 24/7 operation, sensitive IT loads and SLAs require high availability targets, but concrete percentages should only be communicated after architecture validation and a defined measurement period.
What we deliver: Modular UPS systems with N+1 or 2N redundancy, hot-swap modules — capacity scales, maintenance is performed without downtime. Battery monitoring (impedance, temperature) enables predictive maintenance. SNMP/Modbus integration with the existing data center infrastructure management (DCIM) system. Generator + fuel resupply contract for multi-day autonomy. PUE optimization with EMS.
Recommended solutions: Uninterruptible Power Supply Backup Power Industrial Energy Management
Manufacturing / industrial sites
Typical problem: Production line downtime means lost output, scrap, contractual penalties. Sensitive CNC, robotic controls and production PLCs do not tolerate voltage irregularities. At the same time, peak-demand penalties and rising electricity bills push energy efficiency projects onto the agenda. The two questions (continuity + cost) meet on the same infrastructure.
What we deliver: Sized industrial UPS systems on critical lines (online (double-conversion) UPS; output voltage distortion as specified in the datasheet of the specific type). Submetering networks (production line, HVAC, compressed air segments). C&I energy storage for peak shaving with EMS control. Generators for longer outages. Vendor-independent design — we service equipment from multiple manufacturers.
Recommended solutions: Uninterruptible Power Supply Industrial Energy Management Backup Power
Telecommunications
Typical problem: Outage of a base station, switching center or optical node causes coverage loss — emergency calls may become unreachable, with possible regulatory consequences. Sites are often small, with limited cooling and minimal human presence. The 48 VDC industry standard must be followed and full supervision needs to be remote.
What we deliver: Modular 48 VDC power systems with hot-swap rectifiers and integrated battery monitoring (AGM, LiFePO4). N+1 module redundancy. SNMP-based remote supervision — voltage, current, temperature and battery state trends are visible centrally. Combined system with UPS for critical AC loads (cooling, control). With scheduled preventive maintenance, battery replacement is planned from measured capacity, taking the manufacturer's design life into account.
Recommended solutions: DC Power Systems Uninterruptible Power Supply Backup Power
Banks / financial institutions
Typical problem: IT system outage means transaction failure and ATM network errors, and can also create compliance risk. Back-office servers, card transaction systems and branch communications require continuous power. Business continuity requirements are set by the institution's regulatory environment and internal policies; we size redundancy to meet them. Beyond that, the large branch network creates a substantial site fleet management need.
What we deliver: Online (double-conversion) UPS systems with redundant feeds and fast cut-over. The back-office data center runs 2N redundancy; branch sites run N+1 or stand-alone UPS. Generators at central sites. SLA-based maintenance contract with unified supervision — the branch fleet managed under one contract. SNMP integration with the existing banking SOC platform.
Recommended solutions: Uninterruptible Power Supply Backup Power
Office buildings
Typical problem: In modern Class A office leases, ESG reporting and green certification (BREEAM, LEED) are lease differentiators. Rising electricity costs, tenant expectations for green infrastructure (EV charging, solar) and tenant peak management appear on the agenda together. Operations have traditionally been reactive, while tenants expect a proactive system.
What we deliver: EV charging infrastructure in the parking facility (mixed AC + DC, OCPP-based CPMS). Submeter network per tenant unit, support for common-cost allocation. C&I solar inverters and energy storage for self-consumption optimization. Energy management software with reports accessible to both owner and tenants. UPS for critical IT and control equipment.
Recommended solutions: EV Charging Infrastructure Industrial Energy Management Uninterruptible Power Supply
Hospitals
Typical problem: Power outage means a life-threatening situation — medical imaging, intensive care, respiratory support and operating rooms are all power-dependent. Backup power requirements are set by the installation standard (MSZ HD 60364-7-710) and the medical classification of the rooms, which we take into account together with the facility designer; the UPS units installed are built to the IEC/EN 62040 product standard family. Budget constraints are common — the solution must be demonstrably cost-effective.
What we deliver: Backup power sized for critical hospital loads: online UPS for critical clinical departments (operating room, intensive care, imaging) and a generator with ATS sized for the critical load. Battery monitoring and scheduled maintenance under SLA. Load test reports can also be used for operator and authority inspections. Remote supervision feeding into the hospital technical department's monitoring interface.
Recommended solutions: Uninterruptible Power Supply Backup Power
Utilities
Typical problem: Electricity, water and gas utilities run their protection and control systems from DC supply (220 VDC, 110 VDC). A substation DC supply loss or protection system outage can trigger a regional grid event. Regulatory and operator requirements are strict, and systems must be documented and auditable; substation communication is typically based on IEC 61850.
What we deliver: Redundant 220 VDC systems for substations — modular rectifier, OPzV or LiFePO4 battery bank, IEC 61850 SCADA integration. For water and gas pump stations, pressure-boosting houses and gas regulator stations, combined UPS + generator systems. For phased replacements, a controlled load transfer according to an approved changeover plan; a changeover without downtime depends on the existing infrastructure.
Recommended solutions: DC Power Systems Backup Power
Railways
Typical problem: Rail signaling, interlocking and station communication systems run on 72 VDC or 110 VDC supply. Rail operations do not tolerate unplanned outages — operational safety, MÁV/GYSEV regulations. EN 50121 covers railway EMC, EN 50155 covers rolling stock electronics, and EN 50125 covers environmental conditions (such as temperature classes); the applicable class depends on the installation location.
What we deliver: 72/110 VDC power systems with EN 50121-4 compliance as declared by the manufacturer. Battery banks typically lead-pure or LiFePO4. Redundant DC bus configuration with parallel rectifier modules — maintenance without downtime. Site Acceptance Test (SAT) reports for the rail operator audit. Design accounts for trackside work windows.
Recommended solutions: DC Power Systems Uninterruptible Power Supply
Didn't find your industry?
Our experience is not limited to the sectors above — if power supply is critical for you, we can help. We also work in specialist fields (food processing, chemical industry, sports infrastructure, energy tender projects).
We respond within 24 hours on business days.