Key specifications at a glance

  • Rated power: 200 kW DC + 2 × 22 kW AC (UFC 200); 500 kW DC (UFC 500)
  • Output voltage and current: 200–920 V DC; CCS cable and connector max 400 A DC (UFC 200), CCS2 cable max 500 A DC (UFC 500)
  • Simultaneous charging: UFC 200: 2 DC and 2 AC charging points, four vehicles at once; UFC 500: two vehicles at once, max 250 kW each
  • OCPP: 1.5 and 1.6, hardware-ready for OCPP 2.0 (UFC 200); 1.5 and 1.6J (UFC 500)
  • Certified metering: Eichrecht (UFC 200); MID, Eichrecht, LNE – after certification, according to the manufacturer (UFC 500)
  • Protection rating: IP55; enclosure IK10, display IK08

Applications

  • Fast charging corridors, public and roadside charging: DC charging with a 200–920 V output range.
  • Fuel and service stations: several vehicles served simultaneously from one cabinet.
  • Parking facilities and transit hubs: DC charging points combined with AC charging points on the UFC 200.
  • Logistics fleets: DC charging at fleet and industrial sites.
  • Heavy-duty vehicle charging (UFC 500): 500 A CCS2 cable; up to 250 kW per vehicle with two vehicles charging at once, up to 500 A DC at 920 V for a single vehicle.

Delta Ultra Fast Charger models

Delta Ultra Fast Charger models
Model Rated power Distinguishing features
UFC 200 200 kW DC + 2 × 22 kW AC 2 DC (CCS + CHAdeMO) and 2 AC (Type 2) charging points, four vehicles at once; Eichrecht compliant
UFC 500 500 kW DC (2 × 250 kW) Two vehicles at once, 500 A non-liquid-cooled CCS2 cable; also for heavy-duty vehicles

DC fast charger technical specifications

DC fast charger technical specifications
Parameter Value
Rated power 200 kW DC + 2 × 22 kW AC (UFC 200); 500 kW DC, 2 × 250 kW (UFC 500)
AC connection Three-phase (L1, L2, L3, N, PE); dual AC connection on UFC 500
AC voltage 400 V RMS (L-L) ±10%
Grid frequency 50 / 60 Hz
Nominal input current UFC 200: 380 A RMS at maximum power (200 kW DC + 44 kW AC); UFC 500: 725 A RMS at maximum power, dual AC connection (datasheet value; the manufacturer does not state whether it is a total or a per-feed value)
Power factor / THDu 0.99 / 1.5%
Transient overvoltage protection Class II / C
Output voltage 200–920 V DC
Output current UFC 200: max 500 A DC at 400 V, 250 A DC at 800 V at the charger output; CCS cable and connector rated 400 A DC. UFC 500: max 2 × 500 A DC at 500 V, 500 A DC at 920 V; CCS2 cable rated 500 A DC (non-liquid-cooled)
CCS outlet compliance IEC 61851-23 and -24, IEC 62196-3, DIN 70121; ISO 15118-2: listed under compliance for the UFC 500, “Prepared for ISO 15118-2” on the UFC 200
CHAdeMO outlet 125 A DC, 500 V DC; IEC 61851-23 and -24, JEVS G 105 Rev. 1.2
Cable length / reach distance UFC 200: 3.2 m / 2.2 m (optional 5 m / 3.7 m); UFC 500: 5 m / 4 m
Output protection Overcurrent, undervoltage, overvoltage, short circuit, ground fault and isolation monitoring
AC charging point (UFC 200) 2 × Type 2, 400 V RMS, 3 × 32 A RMS, 22 kW; RCD Type A 30 mA + 6 mA DC leakage current detection (IEC 62955); IEC 62196-2 Mode 3
Power modules (UFC 200) Modular design, dynamic power management
User interface 7-inch LCD; 5 buttons; English, up to 4 additional languages on request; emergency stop button optional
Local authentication UFC 200: RFID, optional NFC credit card terminal, Autocharge; UFC 500: RFID, app, payment terminal, Autocharge, Plug & Charge (ISO 15118-2)
Network interface Ethernet, cellular (2G / 3G / 4G)
Back-end protocol OCPP 1.5 and 1.6, hardware-ready for OCPP 2.0 (UFC 200); OCPP 1.5 and 1.6J (UFC 500)
Energy management Modbus TCP for load management and energy management system integration
Certified metering Eichrecht (UFC 200); MID, Eichrecht, LNE – after certification, according to the manufacturer (UFC 500)
Cooling Forced air
Dimensions (W × H × D) 859 × 2,079 × 998 mm (UFC 500; including charging connectors, subject to variants)
Weight UFC 200: 550 kg; UFC 500: 700 kg (including charging connectors, subject to variants)
Protection rating IP55; enclosure IK10, display IK08
Operating temperature UFC 200: −25 °C to +50 °C; UFC 500: −25 °C to +45 °C
Storage temperature −40 °C to +80 °C
Relative humidity < 95%, non-condensing
Altitude max 2,000 m
Safety standards UFC 200: IEC 61851-1, IEC 61851-23; UFC 500: IEC 61851-1, EN 61439-7, EN 17186
EMC UFC 200: EN 55011, IEC 61851-21-2; UFC 500: IEC 61851-21-2, EN 62311, EN 62479
Accessibility DIN 18040

Source: Delta Electronics manufacturer product pages (Ultra Fast Charger 200kW and 500kW, en-GB) and the specification tables published on them, March 2024 (UFC 200) and October 2024 (UFC 500). Specifications are subject to change by the manufacturer.

How to choose

Vehicle mix and charging points

Where passenger cars and AC-charging vehicles share the site, the UFC 200 provides two DC (CCS and CHAdeMO) and two 22 kW Type 2 AC charging points from one cabinet, for four vehicles. Where two vehicles need high power – including heavy-duty vehicles – the UFC 500 delivers up to 250 kW per vehicle through a 500 A CCS2 cable.

Connector rating

The UFC 200 output delivers 500 A at 400 V, but its CCS cable is rated 400 A DC; the UFC 500 CCS2 cable is rated 500 A DC. Check the vehicles' charging current requirements against the cable rating.

Grid connection

At maximum power, the UFC 200 draws 380 A RMS nominal input current and the UFC 500 725 A RMS; the UFC 500 uses a dual AC connection. The datasheet does not state whether the 725 A is a total or a per-feed value, so determine the design current for each feed from the manufacturer's installation documentation. Both models connect to a 400 V three-phase supply. Available grid capacity drives the model choice early in the project; across several chargers, the interface documented by the manufacturer for dynamic load management (DLM / load balancing) is an external energy management system connected over Modbus TCP; load management through the charge point management system (CPMS) requires confirmed charger, firmware and CPMS compatibility for the project.

Certified metering and communication

The UFC 200 provides Eichrecht metering; for the UFC 500, the manufacturer lists MID, Eichrecht and LNE metering, with compliance applying after certification; check the current certification status before ordering. Plug & Charge per ISO 15118-2 is among the UFC 500 local authentication methods; the UFC 200 is described as prepared for ISO 15118-2.

Related services and products

Energom Electronic Kft. is an official distributor of Delta Electronics. Energom assesses the site's grid supply, sizes the charging station, installs and commissions Ultra Fast Charger units, configures the OCPP back-end connection and energy management integration, and carries out maintenance. Services across the Central and Eastern European region; product delivery across Europe.

FAQ

How many vehicles can charge at once on the Delta Ultra Fast Charger?

The Delta Ultra Fast Charger UFC 200 charges four vehicles at once: two on DC (CCS and CHAdeMO) and two on 22 kW Type 2 AC charging points. The UFC 500 charges two vehicles at once, at up to 250 kW each.

Does the Delta Ultra Fast Charger support ISO 15118 Plug & Charge?

In the Delta Ultra Fast Charger family, Plug & Charge (ISO 15118-2) is listed among the UFC 500 local authentication methods. The UFC 200 is only prepared for ISO 15118-2; the manufacturer does not state full support for it.

Which OCPP versions does the Delta Ultra Fast Charger support?

The Delta Ultra Fast Charger UFC 200 supports OCPP 1.5 and 1.6; the manufacturer describes the hardware as ready for OCPP 2.0 and does not state working OCPP 2.0 support. The UFC 500 supports OCPP 1.5 and 1.6J.

Is the Delta Ultra Fast Charger suitable for heavy-duty vehicles?

The manufacturer positions the Delta UFC 500 for public and heavy-duty vehicle charging: it charges two vehicles at once at up to 250 kW each, through a 500 A non-liquid-cooled CCS2 cable. With a single vehicle, the output is up to 500 A DC at 920 V, approximately 460 kW according to the manufacturer.

Request a quote

For a quote, tell us the site's grid connection and available capacity, the vehicle types and connectors to be served, the number of vehicles charging at the same time, and your certified metering, payment and back-end requirements.

Request a Quote

We respond within 24 hours on business days.

Request a Callback