Key specifications at a glance

  • Rated power: 50 kW DC; 22 kW AC (32 A per phase); 72 kW total system power
  • Output voltage: CCS: 200–920 V DC, max 166 A; CHAdeMO: 200–500 V DC, 125 A
  • Connectors, simultaneous charging: 2 DC + 1 AC outlet working simultaneously; the two DC outlets share 50 kW
  • OCPP: 1.5 and 1.6 (tested with OCTT)
  • Energy management: Modbus TCP
  • Protection rating: IP55; enclosure IK10, display IK08

Applications

  • Parking facilities: DC and AC charging from a single unit.
  • Commercial areas: shopping centers and office buildings.
  • Transit hubs: DC fast charging for CCS and CHAdeMO vehicles.
  • Fleet depots: DC and AC charging at one installation point.
  • Ad-hoc charging: credit card payment through the optional NFC card terminal.

Delta DC Wallbox 50 kW configuration

Delta DC Wallbox 50 kW configuration
Model Rated power Distinguishing features
DC Wallbox 50 kW 50 kW DC + 22 kW AC (72 kW total system power) 25 cm deep wall- or floor-mounted DC fast charger with CCS + CHAdeMO + Type 2 socket

Options listed in the manufacturer's specification table: longer DC cables (7 m or 9 m), spring-type cable management system, emergency power off button, NFC credit card terminal, additional user interface languages.

DC fast charger technical specifications

DC fast charger technical specifications
Parameter Value
Rated power 50 kW DC; 22 kW AC (32 A per phase); 72 kW total system power
Grid connection Three-phase (L1, L2, L3, N, PE)
AC voltage 230 V / 400 V
Grid frequency 50 Hz / 60 Hz
Input current 110 A nominal; max 125 A
Power factor / THDu 0.99 / 1%
Input protection Overcurrent protection, overvoltage protection (class II)
CCS outlet 200–920 V DC, max 166 A
CHAdeMO outlet 200–500 V DC, max 125 A; 50 kW nominal power
DC nominal current 125 A at 400 V (CCS and CHAdeMO)
DC cable length CCS: 5 m (optional 7 m, 9 m); CHAdeMO: 4 m (optional 7 m, 9 m)
DC outlet protection Ground fault monitoring, isolation monitoring
DC outlet compliance CCS: IEC 61851-23 and -24, IEC 62196-3, DIN 70121; CHAdeMO: IEC 61851-23 and -24, JEVS G 105 (Rev. 1.2)
AC outlet T2S socket (IEC 62196-2), 230 V / 400 V, 22 kW (32 A per phase)
AC outlet protection RCD Type A (AC 30 mA) and RDC-DD (DC 6 mA)
AC outlet compliance IEC 61851-1, IEC 62196-2
User interface 7-inch LCD; 5 context-sensitive illuminated buttons; emergency power off (optional); LED stripes indicating the status of each DC charge point
Languages English (optional: up to four additional languages)
Authentication, payment RFID; NFC credit card terminal with LC display and PIN pad (optional, different models available)
Cellular connectivity 2 modems (1 back-end connection, 1 service access); 2G / 3G / 4G; Mini-SIM
Ethernet RJ45; back-end connection via OCPP 1.5 and OCPP 1.6 (tested with OCTT)
Energy management Modbus TCP
Cooling Forced air
Dimensions (W × H × D) 650 × 1,200 × 250 mm (excluding charging connectors)
Weight 115–165 kg (depending on configuration, excluding charging connectors)
Cable management Spring-type cable management system (optional), with a 3.9 m cable radius; the charging connector reaches either side of the vehicle
Mounting Wall or floor mounting
Protection rating IP55; enclosure IK10, display IK08
Operating temperature −25 °C to +50 °C
Storage temperature −40 °C to +80 °C
Relative humidity < 95%, non-condensing
Altitude max 2,000 m
EU Low Voltage Directive IEC 61851-1, IEC 61851-22, IEC 61851-23, IEC 62479
EU EMC Directive EN 55011, IEC 61851-21-2
Accessibility DIN 18040

Source: Delta Electronics manufacturer product page (DC Wallbox 50 kW, en-GB) and the specification table published on it, July 2025. Specifications are subject to change by the manufacturer.

How to choose

DC and AC charging in one unit

The DC Wallbox 50 kW combines CCS and CHAdeMO DC outlets with a 22 kW Type 2 AC socket; all three outlets can be used at the same time, with the two DC outlets sharing 50 kW. For a mixed fleet of CCS, CHAdeMO and AC-charging vehicles, one installation point covers the different needs.

Grid supply

The charger requires a three-phase connection, with 110 A nominal and max 125 A input current. During sizing, assess the capacity of the existing supply together with the site's other loads; across several chargers, the interface documented by the manufacturer for dynamic load management (DLM / load balancing) is an external energy management system connected over Modbus TCP; load management through the charge point management system (CPMS) requires confirmed charger, firmware and CPMS compatibility for the project.

Placement and cable management

The 650 × 1,200 × 250 mm unit mounts on a wall or on a floor pedestal. The CCS cable is 5 m and the CHAdeMO cable 4 m as standard, both also available in 7 m or 9 m; the optional spring-type cable management system gives a 3.9 m cable radius, and the charging connector reaches either side of the vehicle.

Authentication and payment

RFID authentication is standard. For public ad-hoc charging, an optional NFC credit card terminal with LC display and PIN pad is available.

Related services and products

Energom Electronic Kft. is an official distributor of Delta Electronics. Energom assesses the site's grid supply, sizes and installs the DC Wallbox 50 kW, commissions it, configures the OCPP back-end connection and energy management integration, and carries out maintenance. Services across the Central and Eastern European region; product delivery across Europe.

FAQ

How many vehicles can charge at once on the Delta DC Wallbox 50 kW?

Three: the Delta DC Wallbox 50 kW's two DC outlets (CCS and CHAdeMO) and the 22 kW Type 2 AC socket work simultaneously. The two DC outlets share 50 kW, and total system power is 72 kW.

Which connectors does the Delta DC Wallbox 50 kW have?

The Delta DC Wallbox 50 kW has a CCS outlet (200–920 V DC, max 166 A), a CHAdeMO outlet (200–500 V DC, max 125 A) and a T2S Type 2 AC socket (22 kW, 32 A per phase).

Does the Delta DC Wallbox 50 kW accept credit card payment?

Yes: the Delta DC Wallbox 50 kW is available with an optional NFC credit card terminal, which has an LC display and PIN pad; the manufacturer offers several terminal models. RFID authentication is standard.

Which OCPP versions does the Delta DC Wallbox 50 kW support?

The Delta DC Wallbox 50 kW connects to a charge point management system (CPMS) via OCPP 1.5 or OCPP 1.6, tested with OCTT, over Ethernet or a 2G / 3G / 4G cellular link. It integrates with an energy management system over Modbus TCP.

Request a quote

For a quote, tell us the site's grid connection and available capacity, the planned mounting (wall or pedestal), the connector types your vehicles use, the required cable length, and your back-end and payment requirements.

Request a Quote

We respond within 24 hours on business days.

Request a Callback