Key specifications at a glance

  • Output power factor: 1.0 (1,000 / 1,500 / 2,200 / 3,000 W)
  • Topology: online, double-conversion; VFI-SS-111 (IEC 62040-3)
  • Efficiency (online mode): max 93.7%
  • Efficiency (ECO / SMART ACTIVE mode): 98%

Applications

  • Servers and storage systems, including 19-inch rack cabinet installations
  • VoIP telephony and network equipment
  • Medical systems
  • Industrial applications
  • Emergency systems: emergency lighting, fire detection and extinguishing systems, alarms

Sentinel Dual2 models

Sentinel Dual2 models
Model Rated power Distinguishing feature
SD2 1000 (A3) 1,000 W internal battery, 425 mm deep enclosure
SD2 1500 (A5) 1,500 W internal battery, 425 mm deep enclosure
SD2 2200 (A3) 2,200 W internal battery, 625 mm deep enclosure, also with a C19 output socket
SD2 2200 ER 2,200 W no internal battery, higher-current charger (max 6 A) for extended runtime
SD2 3000 (A5) 3,000 W internal battery, 625 mm deep enclosure, also with a C19 output socket
SD2 3000 ER 3,000 W no internal battery, higher-current charger (max 6 A) for extended runtime

UPS technical specifications

UPS technical specifications
Parameter Value
Input rated voltage 220 / 230 / 240 V, single-phase
Input voltage range without battery intervention 140–276 V at 50% load; 184–276 V at 100% load
Input voltage tolerance 230 V ±20%
Maximum permitted input voltage max 300 V
Input frequency 50 / 60 Hz ±5%
Input power factor 1, with sinusoidal current draw
Bypass voltage range lower threshold adjustable 180–200 V, upper threshold 250–264 V
Output voltage 220 / 230 / 240 V, software-selectable
Output frequency 50 or 60 Hz selectable, or self-learning
Output voltage distortion <2% with linear load; ≤3.5% with non-linear load
Output voltage regulation static: ±1%; dynamic: ≤5% within 20 ms
Crest factor 3:1
Overload capacity (inverter) overload below 150%: 4 s; 150% overload: 1 s
Battery internal VRLA AGM lead-acid (no water topping-up required), hot-swappable – SD2 1000, 1500, 2200, 3000; ER models have no internal battery
Recharge time 2–4 h (SD2 1000, 1500, 2200, 3000)
Charging current max 6 A (SD2 2200 ER, SD2 3000 ER)
Battery expansion external BTC SD2 battery cabinets, 36 V and 72 V versions (SD2 1000, 2200, 3000 and ER models); the SD2 1500 is not expandable according to the manufacturer's data table
Communications USB; RS232 and opto-isolated contacts on RJ45; communications slot (Modbus/Jbus, TCP/IP-SNMP, relay contacts); R.E.P.O.; Bluetooth (UPStoolsBT app)
Input connector 1× IEC 320 C14 (10 A) – SD2 1000 and 1500; 1× IEC 320 C20 (16 A) – SD2 2200 and 3000 (including ER models)
Output sockets 8× IEC 320 C13 (10 A) – SD2 1000 and 1500; 8× IEC 320 C13 (10 A) + 1× IEC 320 C19 (16 A) – SD2 2200, 3000 and ER models
Dimensions (W × D × H) tower: 87 × 425 × 450 mm (SD2 1000, 1500), 87 × 625 × 450 mm (SD2 2200, 3000 and ER models); rack: 19-inch × 425 mm × 2U or 19-inch × 625 mm × 2U
Net weight 15 kg (SD2 1000); 16 kg (SD2 1500); 24.8 kg (SD2 2200); 12.5 kg (SD2 2200 ER); 27.2 kg (SD2 3000); 12.7 kg (SD2 3000 ER)
Surge protection 300 J
Operating temperature 0–40 °C (recommended for battery life: 20–25 °C)
Relative humidity 5–95%, non-condensing
Noise level <40 dBA at 1 m, ECO mode
Standards and directives VFI-SS-111 (IEC 62040-3); safety: IEC EN 62040-1; EMC: IEC EN 62040-2; 2014/35/EU (LVD), 2014/30/EU (EMC); RoHS compliant
Certification GS Nemko
Color RAL 9005

Source: Riello UPS catalog sheet (DATSD2A1Y26AREN, January 2026) and Riello UPS product page model tables (November 2026). Specifications are subject to change by the manufacturer.

How to choose

Power requirement

The range covers 1,000, 1,500, 2,200 and 3,000 W models. With a 1.0 output power factor, the full rating is available as real power, (for example SD2 1000: 1,000 VA and 1,000 W). When sizing, check both the total protected load in watts and in VA: neither may exceed the model's rating, so with a low load power factor the VA value can be the deciding limit.

Runtime: internal battery or ER model

SD2 1000, 1500, 2200 and 3000 use internal, hot-swappable VRLA AGM batteries with a 2–4 h recharge time; all except the SD2 1500 can also take external battery cabinets. For longer runtime, the SD2 2200 ER and SD2 3000 ER have no internal battery, use a charger of up to 6 A and run on external BTC SD2 battery cabinets.

Installation space and depth

Every model installs as a 2U rack unit or as a tower: rotate the display and fit the supplied handles or optional rails. SD2 1000 and 1500 are 425 mm deep; the 2200 and 3000 models are 625 mm deep (enclosure depth). In a rack cabinet, check the usable mounting depth and the rail load rating against the unit weight (up to 27.2 kg).

Connections

SD2 1000 and 1500 use a C14 input connector; the 2200 and 3000 models use C20. The 2200 and 3000 models, including the ER versions, add a 16 A C19 output socket; choose one of these if the protected equipment needs a 16 A C19 UPS outlet (it connects with a C20 plug).

Monitoring and remote shutdown

The communications slot takes TCP/IP-SNMP boards for network monitoring, Modbus/Jbus boards for building management integration and relay contact boards for simple signaling. Configuration also works over Bluetooth with the UPStoolsBT app.

Related services and products

Energom Electronic Kft. is an official distributor of Riello UPS. Energom sizes Sentinel Dual2 systems to the load and the required runtime, then handles installation, commissioning and scheduled maintenance. Services across the Central and Eastern European region; product delivery across Europe.

FAQ

Can the Sentinel Dual2 battery be replaced during operation?

Yes. According to the manufacturer, the internal VRLA AGM batteries of the SD2 1000, 1500, 2200 and 3000 can be replaced without switching off the unit and without interrupting the load (hot swap). ER models have no internal battery.

How can the Sentinel Dual2 runtime be extended?

The Sentinel Dual2 runtime is extended with external BTC SD2 battery cabinets, available in 36 V and 72 V versions. The SD2 1500 is not expandable according to the manufacturer's data table. For long runtimes, the SD2 2200 ER and SD2 3000 ER are recommended, with a charging current of up to 6 A.

Does the Sentinel Dual2 fit a 19-inch rack cabinet?

Yes. Every Sentinel Dual2 model is 2U high and works in tower or rack position by rotating the display. The enclosure is 425 mm deep (SD2 1000, 1500) or 625 mm deep (SD2 2200, 3000 and ER models); check the rack cabinet's usable mounting depth and rail load rating before installation.

How efficient is the Sentinel Dual2?

The Sentinel Dual2 reaches up to 93.7% efficiency in online (double-conversion) mode and 98% in ECO and SMART ACTIVE modes.

Request a quote

For a quote, share the protected load in watts and VA (or its power factor), the required runtime, the installation format (rack or tower, usable rack depth) and the plug types of the connected equipment.

Request a Quote

We respond within 24 hours on business days.

Request a Callback