What This Means for You
For industrial electricity users, reducing peak demand can be a significant savings opportunity: depending on the tariff, the capacity charge is based on contracted or measured peak demand, so savings depend on the tariff, the load profile and — where capacity is contracted — whether the contracted capacity can be changed. A properly sized energy storage system covers part of the load from stored energy during peak periods and recharges when prices are low. Alongside a solar PV system, it also stores daytime surplus generation.
The HoyUltra 2000M combines the LFP battery, BMS, power conversion system (PCS), optional static transfer switch (STS), thermal management and fire protection in a single container. The factory-integrated design can reduce on-site installation work compared with a system assembled from separate components.
Energom sizes the system to the site's load profile, grid connection conditions and target function, and also handles installation, commissioning and maintenance.
Key Features
- Models: HESS-2088-2h (1 MW / 2.088 MWh) and HESS-2610-2h (1.25 MW / 2.61 MWh), max AC power at 50 °C
- Battery: LFP (lithium iron phosphate) cells, 3.2 V / 314 Ah; rated charge and discharge rate 0.5P
- Round-trip efficiency: up to 91%
- Cooling and protection: liquid cooling, IP55, C4 corrosion class (C5 optional)
- Fire protection: combustible gas, smoke and heat detectors, compartment-level aerosol suppression, water suppression, integrated ventilation
- Grid connection: 400 V AC, 50 or 60 Hz; black start and grid-forming operation; optional static transfer switch with transfer time below 20 ms
- Communication: CAN, RS485, Ethernet; Modbus TCP, MQTT; multiple containers can be connected in parallel
- Compliance: including EN 50549-1/-2/-10, IEC 62619, VDE-AR-N 4105, NC RfG
Application Areas
- Peak shaving — lower capacity charges for factories and logistics centers, depending on the tariff and whether the contracted capacity can be changed
- PV self-consumption — storing surplus generation from existing or planned C&I solar systems
- Time-of-use and peak-valley arbitrage — charging at low and discharging at high price periods
- Backup power — supplying critical loads during grid outages, in island mode with the optional static transfer switch (STS)
- Virtual power plant (VPP) — aggregated participation in flexibility services
Availability and Enquiries
The HoyUltra 2000M is available to order. Accurate sizing requires the site's consumption data (15-minute interval data or sub-meter export), the grid connection capacity and the target function. Energom's engineers use this data to prepare a payback calculation and a technical proposal; we respond within 24 hours on business days.
Data source: Hoymiles HoyUltra 2000M datasheet, Global REV V0.9, 2026.