Key specifications at a glance

  • Rated power: 200 kW (A200), 300 kW (A300), 400 kW (A400); upgradable from 200 or 300 kW to 400 kW
  • Output voltage: 150–980 V DC; 600 A continuous with liquid-cooled CCS cable
  • Connectors, simultaneous charging: 2 outlets; dynamic sharing in 50 kW steps (A400: from 100 kW minimum output)
  • OCPP: 1.6J and 2.0.1; ISO 15118-2 (ISO 15118-20 in development)
  • Certified metering: MID, Eichrecht, LNE
  • Protection rating, efficiency: IP54 / IK10; max 97%

Applications

  • High-power public charging at regional and urban locations
  • Sites that scale with demand: start at 200 or 300 kW and upgrade on site to 400 kW
  • Paid public charging: credit or debit card, mobile app, RFID or Plug & Charge authentication, with MID-, Eichrecht- and LNE-compliant metering

ABB A-Series models (A200, A300, A400)

All three models share the same charger body dimensions (2,256 × 790 × 810 mm, H × W × D) and output voltage range; according to ABB, the 200, 300 and 400 kW configurations are built on field-upgradable power modules.

ABB A-Series models (A200, A300, A400)
Model Rating Distinguishing feature
A200 200 kW entry configuration; field-upgradable to 400 kW
A300 300 kW mid configuration; field-upgradable to 400 kW
A400 400 kW full configuration; 50 kW sharing granularity from 100 kW minimum output

DC fast charger technical specifications

DC fast charger technical specifications
Parameter Value
Rated power A200: 200 kW; A300: 300 kW; A400: 400 kW; upgradable from 200 or 300 kW to 400 kW
Output voltage 150–980 V DC
Output current by connector liquid-cooled CCS: 600 A continuous; phase-cooled CCS: max 600 A peak
Outlets, power sharing 2 outlets; dynamic sharing in 50 kW steps (A400: from 100 kW minimum output)
Connector options CCS2 liquid-cooled or phase-cooled
Efficiency max 97%
Standby power 156 W
Nominal input voltage 400 V AC (±10%)
Nominal input current (RMS) A200: 306 A; A300: 460 A; A400: 612 A
Frequency 50–60 Hz (±5%)
Grounding systems TN-C, TN-C-S, TN-S, TT
Power factor > 0.99 at full load
Total harmonic distortion (THD) < 3%
Overvoltage category; SPD; SCCR III; Type 1 + 2 SPD; SCCR 50 kA
Inlet cable per phase (no neutral), max 2 × 300 mm²; max temperature rating for AC inlet cables 90 °C
Charging cable and cable management 4.8 m length (3.5 m reach) or 7 m length (6.3 m reach); 2 × integrated self-retracting swing arm
Display 32-inch HD full-color anti-glare LCD; 1,300 nits; contrast 1,000:1; 4 push buttons
Authentication methods RFID, Autocharge, Plug & Charge, credit and debit card, mobile app
RFID system Mifare ISO 14443 A and B (to part 4), ISO 15693, ISO 18092 and ECMA-340 (NFC); others on request
OCPP 1.6J and 2.0.1
Vehicle communication ISO 15118-2 (ISO 15118-20 in development); DIN SPEC 70121, ISO 15118-3, Autocharge, Plug & Charge
Network connections 3G, 4G, 5G; Ethernet (10/100 Base-T); optional second modem
Certified metering MID, Eichrecht, LNE
Protection rating IP54 / IK10
Enclosure, corrosion resistance high-durability aluminum body; C5-H (ISO 12944)
Installation indoor and outdoor; floor-mounted; pollution degree: Class 3 (outside), Class 2 (inside)
Operating temperature −30 °C to +55 °C with derating
Storage temperature +5 °C to +40 °C (IEC 60721-3-2)
Altitude max 2,000 m
Humidity max 95%, non-condensing
Noise emission (average within 1 m radius, at 25 °C, full power) A200: 62 dB(A); A300: 64 dB(A); A400: 65 dB(A)
Dimensions (H × W × D) 2,256 × 790 × 810 mm (charger body)
Weight A200: 560 kg; A300: 645 kg; A400: 730 kg
Safety and EMC standards IEC 61851-1, IEC 61851-23; EMC: IEC 61851-21-2
RED Directive standards ETSI EN 300 330, ETSI EN 301 489-1, -3, ETSI 301 489-52, ETSI EN 301 908-13, EN 50364 (RFID), IEC 62311:2019, EN IEC 62311:2020 (4G test)
Additional standards DC vehicle connector compliant with IEC 62196-1, IEC 62196-3; cabinet IP rating according to IEC 60529
Environmental declaration ISO 14025 Environmental Product Declaration (EPD)

Source: ABB A-Series (A400, A300, A200) data sheet, V3-3 (9AKK108469A5277, September 2026), CE version; ABB E-mobility product page (November 2026). Specifications are subject to change by the manufacturer.

How to choose

Power today and tomorrow

If current utilization does not yet justify full power, the A200 or A300 offers a smaller starting configuration that can be raised on site to 400 kW by adding power modules. The A400 is the full 400 kW configuration.

Grid connection

The CE version requires a 400 V AC (±10%) supply; nominal input current is 306 A for the A200, 460 A for the A300 and 612 A for the A400. If an upgrade is likely, size the supply and the inlet cable (max 2 × 300 mm² per phase) for the final 400 kW configuration.

Cable cooling and charging current

Continuous 600 A charging current requires the liquid-cooled CCS cable; the phase-cooled CCS cable delivers 600 A as a peak value. Cable length is 4.8 m (3.5 m reach) or 7 m (6.3 m reach), depending on parking bay layout.

Connectivity and back end

OCPP 1.6J and 2.0.1 connect the charger to a charge point management system (CPMS). On the vehicle side, ISO 15118-2 and Plug & Charge are available; according to ABB, ISO 15118-20 is in development.

Installation environment

The charger body measures 2,256 × 790 × 810 mm (H × W × D) and weighs 560–730 kg depending on the model, so plan the foundation and delivery route. It is designed for indoor and outdoor installation, rated IP54 / IK10 with C5-H (ISO 12944) corrosion resistance.

Related services and products

Energom Electronic Kft. is an official distributor of ABB. For A-Series projects, Energom handles grid connection and charge point sizing, installation, commissioning and CPMS integration, followed by maintenance. Services across the Central and Eastern European region; product delivery across Europe.

FAQ

Can the ABB A200 be upgraded to 400 kW?

Yes: the ABB A200 (200 kW) and A300 (300 kW) can be upgraded on site to 400 kW by adding power modules.

How does the ABB A400 share power between its two outlets?

The ABB A-Series allocates power dynamically between its two outlets in 50 kW steps; on the A400, sharing starts from a 100 kW minimum output.

What charging current does the ABB A-Series cable deliver?

On the ABB A-Series, the liquid-cooled CCS cable delivers 600 A continuous; the phase-cooled CCS cable delivers 600 A as a peak value. Output voltage is 150–980 V DC.

Does the ABB A400 support ISO 15118-20?

Not yet: the ABB A-Series supports ISO 15118-2 and Plug & Charge; per the ABB data sheet, ISO 15118-20 is in development.

What grid connection does the ABB A-Series need?

The CE version of the ABB A-Series requires a 400 V AC (±10%), 50–60 Hz supply; nominal input current is 306 A (A200), 460 A (A300) or 612 A (A400).

Request a quote

For an accurate quote, describe the site type, the available or planned supply capacity, the initial and final target power (200, 300 or 400 kW), the cable length you need, and the CPMS you use.

Request a Quote

We respond within 24 hours on business days.

Request a Callback