Key specifications at a glance

  • Supply voltage: 18–75 V DC (ORION E, ORION ID:E1); 18–60 V DC (ORION ID:F1); max 0.8 A
  • Interfaces: Gigabit Ethernet, 2 × RS485, 1 × RS232, 1 × USB host; ORION ID:F1 also 1 × CAN (IMBUS)
  • Protocols: SNMP, Modbus, MQTT, HTTP-API; Syslog (ORION E, ORION ID:E1)
  • Operating temperature: −40 to +70 °C
  • Safety standard: IEC/EN 62368-1
  • Dimensions, weight: 83.4 × 40.0 × 205.1 mm, 0.5 kg (E, ID:E1); 83.4 × 40.0 × 203.9 mm, 0.46 kg (ID:F1)

Applications

  • Monitoring and control of telecom power systems.
  • Multi-device sites: supervision of rectifiers, power converters, batteries and third-party equipment over multiple communication interfaces (ORION E, ORION ID:E1).
  • Hybrid and renewable energy sites that prioritize renewable sources and optimize generator operation.
  • Modernization of existing PSC 3 installations (ORION ID:F1).
  • Upgrades of existing ORION-based systems (ORION ID:E1).

ORION controller models

ORION controller models
Model Supply voltage Distinguishing feature
ORION E 18–75 V DC Eltek-branded version of the ORION ID:E1, identical specifications
ORION ID:E1 (ORION Touch) 18–75 V DC touchscreen controller, full backward compatibility with existing ORION-based systems
ORION ID:F1 18–60 V DC mechanically and electrically compatible drop-in replacement for the PSC 3; 1 × CAN (IMBUS)

DC power system controller specifications

DC power system controller specifications
Parameter ORION E ORION ID:E1 ORION ID:F1
DC supply voltage range 18–75 V DC 18–75 V DC 18–60 V DC
Current draw max 0.8 A DC max 0.8 A DC max 0.8 A DC
Display color touch display for local operation color touch display for local operation color touch display for local operation
Remote monitoring links Gigabit Ethernet, RS485, RS232 or modem Gigabit Ethernet, RS485, RS232 or modem Gigabit Ethernet, RS485, RS232 or modem
Serial and other ports 2 × RS485, 1 × RS232, 1 × USB host 2 × RS485, 1 × RS232, 1 × USB host 2 × RS485, 1 × RS232, 1 × USB host, 1 × CAN (IMBUS)
Remote protocols SNMP, Modbus, MQTT, HTTP-API, Syslog, customer-specific protocols SNMP, Modbus, MQTT, HTTP-API, Syslog, customer-specific protocols SNMP, Modbus, MQTT, HTTP-API
Web interface integrated web server for standard browsers; configurable access rights and user profiles integrated web server for standard browsers; configurable access rights and user profiles integrated web server for standard browsers; configurable access rights and user profiles
Battery management battery supervision, automatic battery testing, backup-time prediction, support for multiple battery technologies same as ORION E same as ORION E
PLC functions programmable logic controller functions for monitoring and controlling auxiliary site equipment same as ORION E same as ORION E
Logging configurable event and data logging, statistics, user-defined sampling same as ORION E same as ORION E
Energy-saving functions prioritization of renewable energy sources, optimized generator operation same as ORION E same as ORION E
Compatibility not stated full backward compatibility with existing ORION-based systems drop-in replacement for the PSC 3, mechanically and electrically compatible
Dimensions (W × H × D) 83.4 × 40.0 × 205.1 mm 83.4 × 40.0 × 205.1 mm 83.4 × 40.0 × 203.9 mm
Weight 0.5 kg 0.5 kg 0.46 kg
Operating temperature −40 to +70 °C −40 to +70 °C −40 to +70 °C
Relative humidity max 95%, non-condensing max 95%, non-condensing max 95%, non-condensing
Safety standard IEC/EN 62368-1 IEC/EN 62368-1 IEC/EN 62368-1
EMC EN 55022, Class B EN 55022, Class B EN 55022, Class B

Source: Delta manufacturer product page (EMEA), November 2026. Specifications are subject to change by the manufacturer.

How to choose

How to choose
Situation Recommended model Why
New site with a system voltage within 18–75 V DC ORION ID:E1 or ORION E wide supply voltage range, Syslog and customer-specific protocols
Upgrading an existing ORION-based system ORION ID:E1 Delta states full backward compatibility
Replacing an existing PSC 3 controller ORION ID:F1 mechanically and electrically compatible drop-in replacement with a CAN (IMBUS) port
An Eltek-branded controller is required ORION E Eltek-branded version of the ORION ID:E1, identical specifications

Supply voltage

The ORION E and ORION ID:E1 run on 18–75 V DC, the ORION ID:F1 on 18–60 V DC; all three draw max 0.8 A DC.

Monitoring integration

The protocol of your network management system decides the fit: all three models support SNMP, Modbus, MQTT and HTTP-API, while Delta lists Syslog and customer-specific protocols for the ORION E and ORION ID:E1.

Hybrid sites

According to Delta, the energy-saving functions prioritize renewable sources and optimize generator operation; the PLC functions cover control of auxiliary site equipment.

Related services and products

Energom Electronic Kft. is an official distributor of Delta Electronics. Services across the Central and Eastern European region; product delivery across Europe. For ORION controllers, Energom handles model selection, integration into existing systems, connection to your monitoring system, commissioning and maintenance.

FAQ

What is the difference between the ORION E and the ORION ID:E1?

According to Delta, the ORION E is the Eltek-branded version of the ORION ID:E1 (ORION Touch), with identical specifications: 18–75 V DC supply, color touch display, Gigabit Ethernet, 2 × RS485, 1 × RS232 and 1 × USB host.

Can an ORION controller replace a PSC 3 controller?

A PSC 3 can be replaced with the ORION ID:F1: Delta describes it as a mechanically and electrically compatible drop-in replacement for the PSC 3. It runs on 18–60 V DC and adds 1 × CAN (IMBUS) port.

Which protocols connect the ORION to a monitoring system?

The ORION E, ORION ID:E1 and ORION ID:F1 all support SNMP, Modbus, MQTT and HTTP-API. Delta lists Gigabit Ethernet, RS485, RS232 or modem as remote monitoring links; which protocol is available on which link is confirmed with the quote. The ORION E and ORION ID:E1 also handle Syslog and customer-specific protocols.

What is the operating temperature range of the Delta ORION controller?

ORION controllers operate from −40 to +70 °C at up to 95% relative humidity, non-condensing, and comply with the IEC/EN 62368-1 safety standard.

Request a quote

When requesting a quote, include the system voltage, for an upgrade the existing controller type (for example PSC 3 or an earlier ORION), your monitoring system protocol and the equipment to be supervised.

Request a Quote

We respond within 24 hours on business days.

Request a Callback